10. Cleaning and maintenance
Clean regularly the pellet stove and the exhaust gases system. This ensures the efficient work of the
pellet stove.
IMPORTANT! When cleaning the pellet stove or the exhaust gases system do not use detergents
containing acid or flammable substances.
10.1 Cleaning and maintenance of the exhaust gases tube
TAR is liquid that is formed in consequence of poor combustion that leads to low temperature in the
exhaust gases tube. If there is tar in the exhaust gases tube/chimney it is recommended to isolate it
well. Deposition of tar may cause fire. It is recommended to check and clean the exhaust gases
system at least once during the heating season.
ATTENTION! The exhaust gases system (chimney) must be checked and before the first start of the
pellet stove.
10.2 Cleaning and maintenance of the pellet stove.
Cleaning and maintenance of the pellet stove must be performed regularly. Please, make basic
cleaning after burning from 800 to 1000 kg pellets or once per year.
ATTENTION! FOLLOW THESE STEPS WHEN CLEANING:
Switch OFF the pellet stove
Wait until the pellet stove cools completely.
Switch OFF the power supply.
Do not use flammable detergents.
When making routine check the authorized service must do as following:
Cleaning the fans;
Cleaning all the inaccessible places burner;
Complete check of the ignition system and the pellet loading system;
Complete check of the condition of the insulations ropes on the door and to change it if
needed.
Dismounting and cleaning the T-connection of the exhaust gases system
Complete check of all the electrical parameters;
Issuing an inspection report for the actions performed;
It is necessary to make periodical cleaning of the outer surface of the pellet stove, the door glass, the
insulation rope at the door, the ash tray. Clean the burner and the heat exchanger every day.
Clean the pellet silo every month. . Please, make basic cleaning after burning from 800 to 1000 kg
pellets or once per year
Cleaning the outer surface of the pellet stove
Use soft cloth and neutral cleaning detergents.